Pni RM3000 Sensor Suites Manual de usuario Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 41
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
PNI Sensor Corporation Doc #1015673 r08
RM3000 & RM2000 Sensor Suite User Manual July 2012 Page 18 of 41
Dimensions: mm
Full reel is 5000 pcs. Smaller quantities on cut-tape.
Tape & Reel meets ANSI/EIA standard EIA-418
Figure 3-17: 3D MagIC Tape Dimensions
3.6 Soldering
Figure 3-18 and Table 3-6 provide the recommended solder reflow profile and processing
parameters for Geomagnetic Sensor Suite components. After soldering PNI components to a
board, it is possible to wave solder the opposite side of the PCB.
IMPORTANT: PNI sensors require the use of halide-free solder pastes and processes for
reflow and cleaning. Please contact PNI if you would like recommendations.