User Manual CompassPoint V2Xe Electronic 2-Axis Compass Module

Pagina 2 - List of Figures

V2Xe User Manual – May 2012 Page 8 5 Operation with V2Xe Protocol The following section describes the data structure and the commands used to commu

Pagina 3

PNI Sensor Corporation DOC#1017814 r01 V2Xe User Manual – May 2012 Page 9 5.2 Parameter Formats Note: Floating-point based parameters conform

Pagina 4 - 2 Introduction

V2Xe User Manual – May 2012 Page 10 Signed 8 Bit Integer (SInt8) UInt8-based parameters are unsigned 8-bit numbers. Bit 7 represents the sign of th

Pagina 5 - 3 Specifications

PNI Sensor Corporation DOC#1017814 r01 V2Xe User Manual – May 2012 Page 11 FourCharCode FourCharCode is a four-byte parameter. ASCII Char 1 ASCII C

Pagina 6 - 3.2 Package Information

V2Xe User Manual – May 2012 Page 12 kGetModInfoResp (frame ID 0x02) The response to kGetModInfo is given below. The payload contains the device typ

Pagina 7 - 4 Set-Up

PNI Sensor Corporation DOC#1017814 r01 V2Xe User Manual – May 2012 Page 13 kDeclination (Config. ID 0x01) This sets the declination angle to

Pagina 8 - 4.3 SPI Hardware Protocol

V2Xe User Manual – May 2012 Page 14 the “n” number elements. Damping is only applied to the heading data. This is not a running average but instea

Pagina 9 - *Tri-state when SSN is HIGH

PNI Sensor Corporation DOC#1017814 r01 V2Xe User Manual – May 2012 Page 15 By performing a calibration, the V2Xe identifies local sources of distor

Pagina 10 - 5.1 Datagram Structure

V2Xe User Manual – May 2012 Page 16 kSetCalData (frame ID 0x0E) This frame writes calibration data into the V2Xe using the same frame structure as k

Pagina 11 - 5.2 Parameter Formats

PNI Sensor Corporation DOC#1017814 r01 V2Xe User Manual – May 2012 Page 17 Table 5-4: Component Identifiers Component Component ID Format Units kX

Pagina 12 - Little Endian

PNI Sensor Corporation DOC#1017814 r01 V2Xe User Manual – May 2012 Page i Table of Contents 1 COPYRIGHT & WARRANTY INFORMATION ...

Pagina 13 - 5.4 Module Set-Up

V2Xe User Manual – May 2012 Page 18 After a request for data is sent, a time delay is required for processing and sampling. The time delay required

Pagina 14

PNI Sensor Corporation DOC#1017814 r01 V2Xe User Manual – May 2012 Page 1 1 Copyright & Warranty Information © Copyright PNI Sensor Corporat

Pagina 15

V2Xe User Manual – May 2012 Page 2 2 Introduction Thank you for purchasing PNI Sensor Corporation’s CompassPoint V2Xe (pn 11862). This

Pagina 16 - 5.5 Calibration

PNI Sensor Corporation DOC#1017814 r01 V2Xe User Manual – May 2012 Page 3 3 Specifications 3.1 Performance Specifications Table 3-1: Absolute Ma

Pagina 17

V2Xe User Manual – May 2012 Page 4 Footnotes: 1. Characteristics are subject to change. Values assume supply voltage of 3 VDC. 2. Measurement tak

Pagina 18 - 5.6 Making Measurements

PNI Sensor Corporation DOC#1017814 r01 V2Xe User Manual – May 2012 Page 5 4 Set-Up 4.1 Electrical Connections The V2Xe incorporates two 7-pin SIP

Pagina 19 - (Component ID 5

V2Xe User Manual – May 2012 Page 6 4.2 Mechanical Installation 4.2.1 Mounting Orientation The V2Xe should be mounted horizontally and as level as

Pagina 20

PNI Sensor Corporation DOC#1017814 r01 V2Xe User Manual – May 2012 Page 7 Figure 4-1: Transfer from Host to V2Xe Figure 4-2: Transfer from V2