Pni FieldForce Trax Manual de usuario Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 62
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
PNI Sensor Corporation DOC#1016505 r06
TRAX User Manual Page 5
Table 3-4: I/O Characteristics
Parameter
Value
Communication Interface
RS232 UART & USB
Communication Protocol
PNI Binary
Communication Rate
1
2400 to 921,600 baud
Maximum Data Output Rate
30 samples/sec
Footnote:
1. The TRAX can operate up to 921,600 baud, but native RS232 is limited to
115,200 baud.
Table 3-5: Environmental Requirements
Parameter
Value
Operating Temperature
1
-40C to +85C
Storage Temperature
-40C to +85C
Footnote:
1. To meet performance specifications across this range, recalibration will be
necessary as the temperature varies.
Table 3-6: Mechanical Characteristics
Parameter
Value
Dimensions
(l x w x h)
TRAX Enclosed
6.4 x 5.9 x 2.3 cm
TRAX PCA
3.5 x 4.3 x 1.0 cm
Weight
TRAX Enclosed
75 gm
TRAX PCA
7 gm
Connector
TRAX Enclosed
7 pin ODU, pn K20L0C-P07LCC0-520S
TRAX PCA
9-pin Molex, pn 53780-0970
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 61 62

Comentarios a estos manuales

Sin comentarios