PNI Sensor Corporation Doc 1017252 r03
RM3100 & RM2100 Sensor Suite User Manual Page 13 of 45
Dimensions: mm
Full reel is 5000 pcs. Smaller quantities on cut-tape.
Tape & Reel meets ANSI/EIA standard EIA-418
Figure 3-8: MagI2C MLF Tape Dimensions
3.5 Soldering
Figure 3-9 and Table 3-6 provide the recommended solder reflow profile and processing
parameters for RM3100 components. After soldering PNI components to a board, it is
possible to wave solder the opposite side of the PCB.
IMPORTANT: PNI sensor coils require the use of halide-free solder pastes and processes for
reflow and cleaning. Contact PNI if you would like recommendations.