PNI Sensor Corporation DOC#1014688 r06
TCM User Manual July 2013 Page 28
6.4 Calibration Tab
Note: The default settings are recommended for the highest accuracy and quality of calibration.
6.4.1 Samples
Before proceeding, refer to Section 5 for the recommended calibration procedure
corresponding to the calibration method selected on the Configuration tab.
Clicking the <Start> button begins the calibration process.
If “Automatic Sampling” is not checked on the Configuration tab, it is necessary to click
the <Take Sample> button to take a calibration sample point. This should be repeated
until the total number of samples, as set on the Configuration tab, is taken while changing
the orientation of the module between samples as discussed in Section 5.
If “Automatic Sampling” is checked, the module will need to be held steady for a short
time and then a sample automatically will be taken. Once the window indicates the next
number, the module’s orientation should be changed and held steady for the next sample.
Once the pre-set number of samples has been taken (as set on the Configuration tab) the
calibration is complete.